There are two places where you can update the license on the
dongle:
- Hearing Instrument System Control Panel
- Dongle Update Client
Hearing Instrument System Control
Panel:
Usually you will find a shortcut for Hearing Instrument System
Control Panel on the desktop. Otherwise run one of the following
files, depending on your type of installation:
- Q:\ShellManager\Software\Control Panel\ControlPanel.exe (for
Shellmanager systems)
- C:\Program Files\3Shape\Control Panel\ControlPanel.exe (for
stand-alone installations)
In both cases goto "Administrative Tools" and then choose
either::
- Local Dongle Update (if you open the Control Panel on the pc in
which the dongle is inserted)
- Remote Dongle Update (if you look for a dongle in another
pc)
Dongle Update Client:
This application can be downloaded from the Support
section on www.3Shape.com. If already
installed it is most likely to be found in following
location:
- C:\Program Files\3Shape\Dongle Update Client
To execute the application just doubleclick
"DongleUpdateClient.exe". Note that it must be executed locally on
the pc in which the dongle is insterted.
Internet or manual update?:
Regardless application you would usually just click
"Internet update" to check for available updates
on 3Shape license server. If there are new licenses available it
will automatically be downloaded and applied to the dongle.
However, if you are not connected to the internet you must do a
"Manual update" and in this case please
contact your reseller.
In general the scanner should be calibrated at least once a
month.
Moreover it is advisable to run a calibration if the
scanner receives a blow or has been moved from one place to
another.
When opening a 3Shape application you may receive following
error:
Protection Dongle error
number 20
Software protection dongle error. Program cannot run
The most likely reason for this error
is that there is no license on the dongle for the particular
program you are trying to execute.
To solve the problem you must add a
new license for this type application to your dongle. Please
contact your reseller regarding to this matter.
When opening a 3Shape application you may receive following
error:
Protection Dongle error
number 28/00 49 96 96 00 00
Software protection dongle error. Program cannot run
The most likely reason for this error
is that the dongle driver was not installed properly. If you do not
see a light in the dongle this may be another thing confirming this
theory.
To solve the problem therefore
install/reinstall the dongle driver.
If this is first time to have a
dongle inserted in this pc you should probably start by
downloading and installing the driver software. You can obtain
the driver from the download section of the 3Shape support
homepage. Please contact your reseller if you do not have
access to the download section. To install the driver just
doubleclick the downloaded exe-file and follow the
instructions.
To reinstall the driver rightclick "my
computer" and choose "Properties". Then goto "Hardware" tab and
click "Device Manager". Rightclick the entry for "USB Key Ver.
1.0 Microcosm ltd." (which you will probably find with an
exclamation mark under the "Software Security" header) and
choose "Update driver". Choose to let the installation wizard
"Install the software automatically (Recommended)" and then follow
the rest of the instructions.
When trying to calibrate the scanner you will be asked for a
password. This password is: docal
If a license on your dongle has expired you will get
following message when trying to open the application:
Protection Dongle error
number 25
Application license has expired
In these situations you
should start by performing an Internet Update on the
dongle (please see: How do I update the license on
my dongle?) as there may be an upgrade waiting for you already.
If an Internet Update does not solve the problem, you
should contact your reseller (please note that unless you
bought the system directly from 3Shape we cannot help you with
this matter).
There are two places where you can look for the dongle
number:
- Hearing Instrument System Control Panel
- Dongle Update Client
Hearing Instrument System Control Panel:
Usually you will find a shortcut for Hearing Instrument System
Control Panel on the desktop. Otherwise run one of the
following files, depending on your type of installation:
- Q:\ShellManager\Software\Control
Panel\ControlPanel.exe (for Shellmanager systems)
- C:\Program Files\3Shape\Control Panel\ControlPanel.exe (for
stand-alone installations)
In both cases goto "Administrative Tools" and then choose
either:
- Local Dongle Update (if you open the Control Panel on the
pc in which the dongle is inserted)
- Remote Dongle Update (if you look for a dongle in another
pc)
For both Local and Remote Dongle Update you will find a field
for the Dongle number.
Dongle Update Client:
This application can be downloaded from the Support
section on www.3Shape.com. If already installed you
may find it in following location:
- C:\Program Files\3Shape\Dongle Update Client
To execute the application just doubleclick
"DongleUpdateClient.exe". Note that it must be executed locally on
the pc in which the dongle is insterted. When launched you will see
a field for the Dongle Number.
There are different ways look up the contents of a dongle.
For example:
- 3Shape Hearing Instrument System Control Panel
- Dongle Update Client
Please see "How do I update the license on my dongle?" for
how to launch these application.
Another way to check the contents of a local dongle and at the
same time to see what licenses that currently is being used is
to:
This method is great for checking the licenses on your
Shellmanager server.
When exporting materials in Hearing Instrument Control Panel you
may get following message:
Site ID not set. Export
cannot continue.
The reason for this errormessage is
that no value was specified for the "Site ID" setting. This setting
is among other things being used to identify where export-sme's
origins from.
To correct this problem a value for
"Site ID" must be specified. To set the ID open 3Shape Hearing
Instrument Control Panel and go to "System Settings" and fill in a
value where is says "Site ID". The value specified is
free of choice but could fx. be Companyname and
Country-initials.
In ShellDesigner and EarmouldDesigner you may experience
that the impression is rotating or disappearing out of the screen
even though the spaceball is not being touched.
This behaviour is mostly seen if the spaceball is touched while
it calibrates or right after installation of the spaceball
driver.
To solve this problem simply restart the spaceball driver or
reboot the pc.